Cannabis Extraction Laboratory Safety and Compliance Checklist
This cannabis extraction laboratory safety and compliance checklist ensures compliance with NFPA 1 (Fire Code) for Class I Division 1 hazardous locations, OSHA 29 CFR 1910.106 (Flammable Liquids Standard), IFC (International Fire Code) extraction facility provisions, and state cannabis processor license requirements. Cannabis extraction facilities using flammable solvents have experienced catastrophic explosions when fire codes are not followed.
- Industry: Cannabis
- Frequency: Daily
- Estimated Time: 30-45 minutes
- Role: Extraction Lab Manager / Safety Officer
- Total Items: 30
- Compliance: NFPA 1 Fire Code Hazardous Locations Class I Division 1, OSHA 29 CFR 1910.106 Flammable and Combustible Liquids, IFC International Fire Code Chapter 57 Flammable Finishes, State Cannabis Processor License Requirements, NFPA 58 Liquefied Petroleum Gas Code
Hazardous Area Classification
NEC/NFPA electrical and area classification.
- Extraction area classified as Class I Division 1 or 2 per NEC Article 500?
- All electrical equipment in classified area rated for Class I Div 1/2?
- No ignition sources (open flames, non-rated switches) in classified area?
- Explosion-proof lighting, outlets, and motors installed in classified area?
- All equipment properly grounded and bonded to prevent static discharge ignition?
Ventilation
Solvent vapor control.
- Local exhaust ventilation (LEV) operational in solvent handling areas?
- Minimum air changes per hour (ACH) met per fire marshal approval?
- LEL gas detector operational and alarming at 10% of LEL?
- Makeup air supply providing adequate fresh air to operators?
- HVAC system interlocked with gas detector to activate on alarm?
Solvent Management
Flammable solvent storage and handling.
- Solvent quantity in work area within permitted maximum daily use amount?
- Solvents stored in FM/UL-approved flammable storage cabinets when not in use?
- Solvent receipt, use, and disposal log maintained?
- SDS for all solvents accessible in lab per OSHA HazCom 1910.1200?
- Flammable solvents not stored in glass containers in classified areas?
Fire Suppression and Emergency Equipment
Fire safety equipment.
- Automatic fire suppression system operational and in service?
- CO2 or dry chemical fire extinguishers accessible and within inspection date?
- Emergency solvent supply shutoff accessible and clearly labeled?
- Emergency eyewash station within 10 seconds of solvent handling area?
- Evacuation plan posted and staff trained on emergency procedures?
PPE and Worker Safety
Personal protective equipment.
- Chemical-resistant gloves appropriate for solvent type worn?
- Chemical splash goggles worn during all solvent handling?
- Organic vapor respirator available and worn during open solvent work?
- No solo work during active extraction operations (buddy system in place)?
- All operators trained in extraction SOPs, fire safety, and emergency response?
Extraction Records
Production documentation.
- Batch production records completed for each extraction run?
- Input weight, output weight, and yield percentage recorded per run?
- State tracking system updated with processing batch data?
- Equipment maintenance log current for all extraction equipment?
- Extraction Lab Notes
Related Chemical Safety Checklists
- Cannabis Facility Solvent Handling and Flammable Safety Checklist
- Cannabis CO2 Supercritical Extraction System Safety Checklist
- Cannabis Facility Chemical Storage and Hazardous Materials Compliance Checklist
- HazCom Training Record - FREE PDF
Why Use This Cannabis Extraction Laboratory Safety and Compliance Checklist?
This cannabis extraction laboratory safety and compliance checklist helps cannabis teams maintain compliance and operational excellence. Designed for extraction lab manager / safety officer professionals, this checklist covers 30 critical inspection points across 6 sections. Recommended frequency: daily.
Ensures compliance with NFPA 1 Fire Code Hazardous Locations Class I Division 1, OSHA 29 CFR 1910.106 Flammable and Combustible Liquids, IFC International Fire Code Chapter 57 Flammable Finishes, State Cannabis Processor License Requirements, NFPA 58 Liquefied Petroleum Gas Code. Regulatory-aligned for audit readiness and inspection documentation.
Frequently Asked Questions
What does the Cannabis Extraction Laboratory Safety and Compliance Checklist cover?
This checklist covers 30 inspection items across 6 sections: Hazardous Area Classification, Ventilation, Solvent Management, Fire Suppression and Emergency Equipment, PPE and Worker Safety, Extraction Records. It is designed for cannabis operations and compliance.
How often should this checklist be completed?
This checklist should be completed daily. Each completion takes approximately 30-45 minutes.
Who should use this Cannabis Extraction Laboratory Safety and Compliance Checklist?
This checklist is designed for Extraction Lab Manager / Safety Officer professionals in the cannabis industry. It can be used for self-assessments, team audits, and regulatory compliance documentation.
Can I download this checklist as a PDF?
Yes, this checklist is available as a free PDF download. You can also use it digitally in the POPProbe mobile app for real-time data capture, photo documentation, and automatic reporting.