Australia Dental Practice Safety Checklist (ADA Guidelines)
This dental practice safety checklist aligns with the Australian Dental Association (ADA) Guidelines for Infection Prevention and Control, AS/NZS 4815 and AS/NZS 4187 instrument reprocessing standards, and Dental Board of Australia requirements. Covers infection control, radiation safety, emergency preparedness, and patient safety in dental settings. Complete monthly or as part of practice accreditation audits.
- Industry: Healthcare
- Frequency: Monthly
- Estimated Time: 30-40 minutes
- Role: Practice Principal / Infection Control Coordinator
- Total Items: 28
- Compliance: ADA Infection Control Guidelines, AS/NZS 4815, AS/NZS 4187, Dental Board of Australia, Radiation Safety Standards
Infection Prevention & Control
Infection control per ADA guidelines and NHMRC recommendations.
- Hand hygiene compliance observed (5 Moments)?
- Appropriate PPE worn during procedures (gloves, mask, eyewear)?
- Clinical surfaces disinfected between patients?
- Dental unit waterline management program in place?
- Single-use items discarded after each patient?
Instrument Reprocessing (AS/NZS 4815/4187)
Instrument cleaning, disinfection, and sterilisation.
- Instrument cleaning protocol followed (manual/ultrasonic)?
- Steriliser (autoclave) validated and cycle records maintained?
- Biological indicators run as per schedule?
- Instrument packaging compliant with standards?
- Sterile storage area clean, dry, and organised?
Radiation Safety
Radiation safety per state/territory radiation legislation.
- Radiation use licence/registration current?
- X-ray equipment tested and serviced per schedule?
- Lead aprons available, used, and inspected?
- Patient exposure records maintained?
- Radiation warning signage displayed?
Patient Safety & Records
Patient safety and clinical record requirements.
- Medical history reviewed and updated at each visit?
- Informed consent obtained for procedures?
- Allergies prominently documented in records?
- Emergency drugs and equipment available and current?
Waste Management
Clinical and hazardous waste management.
- Clinical waste segregated from general waste?
- Sharps containers available and compliant?
- Amalgam waste managed per environmental requirements?
- Licensed waste contractor engaged for clinical waste?
Emergency Preparedness
Emergency equipment and procedures.
- Medical emergency kit accessible and contents current?
- Oxygen supply available and functional?
- AED (defibrillator) available and tested?
- All clinical staff CPR trained and current?
- Additional observations and actions required
Related Healthcare Checklists
- Australia Tattoo & Body Art Hygiene Inspection Checklist
- Healthcare Facility Cleaning Checklist
- Dental Office Infection Control Checklist
- Dental Office Infection Control and OSHA Compliance Inspection Checklist
- Australia Mental Health Facility Inspection Checklist
- Australia Ambulance Vehicle Pre-Trip Check
- Australia Radiology Safety & Compliance Checklist
- Australia Blood Bank Compliance Checklist (TGA)
Related Infection Control Checklists
- Hand Hygiene Compliance Audit Checklist - FREE Download
- Central Line Bundle Audit - FREE Download
- Bloodborne Pathogen Exposure Control - Infection Control Checklist - FREE Download
- Isolation Precautions Checklist - FREE PDF - FREE Download
- Central Line Insertion Bundle Checklist - FREE PDF - FREE Download
- Central Line Maintenance Bundle - FREE PDF - FREE Download
- SSI Prevention Bundle - FREE PDF - FREE Download
- MRSA Screening and Decolonization - FREE PDF - FREE Download
- Healthcare Environmental Cleaning Audit - FREE PDF - FREE Download
- Terminal Room Cleaning Checklist - FREE PDF - FREE Download
Why Use This Australia Dental Practice Safety Checklist (ADA Guidelines)?
This australia dental practice safety checklist (ada guidelines) helps healthcare teams maintain compliance and operational excellence. Designed for practice principal / infection control coordinator professionals, this checklist covers 28 critical inspection points across 6 sections. Recommended frequency: monthly.
Ensures compliance with ADA Infection Control Guidelines, AS/NZS 4815, AS/NZS 4187, Dental Board of Australia, Radiation Safety Standards. Regulatory-aligned for audit readiness and inspection documentation.
Frequently Asked Questions
What does the Australia Dental Practice Safety Checklist (ADA Guidelines) cover?
This checklist covers 28 inspection items across 6 sections: Infection Prevention & Control, Instrument Reprocessing (AS/NZS 4815/4187), Radiation Safety, Patient Safety & Records, Waste Management, Emergency Preparedness. It is designed for healthcare operations and compliance.
How often should this checklist be completed?
This checklist should be completed monthly. Each completion takes approximately 30-40 minutes.
Who should use this Australia Dental Practice Safety Checklist (ADA Guidelines)?
This checklist is designed for Practice Principal / Infection Control Coordinator professionals in the healthcare industry. It can be used for self-assessments, team audits, and regulatory compliance documentation.
Can I download this checklist as a PDF?
Yes, this checklist is available as a free PDF download. You can also use it digitally in the POPProbe mobile app for real-time data capture, photo documentation, and automatic reporting.