Fire Alarm System Annual Inspection and Test Checklist

This fire alarm system annual inspection checklist ensures compliance with NFPA 72-2022 National Fire Alarm and Signaling Code Chapter 14, IFC Section 907, and local Authority Having Jurisdiction (AHJ) requirements. Designed for NICET-certified fire alarm inspection technicians.

  • Industry: Security Services
  • Frequency: Annually
  • Estimated Time: 2-8 hours depending on system size
  • Role: Licensed Fire Alarm Inspector / NICET-Certified Technician
  • Total Items: 14
  • Compliance: NFPA 72-2022 National Fire Alarm and Signaling Code Chapter 14, IFC International Fire Code Section 907, NFPA 70 NEC Article 760 Fire Alarm Circuits, UL 864 Control Units for Fire Alarm Systems, NICET Fire Alarm Systems Inspection and Testing Standards

Fire Alarm Control Panel Status

FACP condition and pre-existing trouble review.

  • FACP displaying normal with no active troubles or supervisory conditions?
  • Panel date and time accurate?
  • Event history log reviewed for pattern of unexplained activations?
  • No physical damage, corrosion, or missing knockouts visible on panel?

Detector and Initiating Device Testing

100% smoke/heat detector testing per NFPA 72.

  • 100% of smoke detectors tested with listed aerosol or test instrument?
  • All heat detectors tested with listed heat source?
  • Duct smoke detectors tested with HVAC shutdown confirmed on activation?
  • All manual pull stations tested and reset?
  • Waterflow and tamper switches tested with central station confirmation?

Notification Appliances and Power

Audible/visual devices and secondary power battery test.

  • All audible notification appliances sounding correctly on alarm?
  • All visual notification appliances (strobes) flashing on alarm?
  • Secondary power batteries load-tested for minimum 24-hour standby + 5 minutes alarm?
  • All alarm signals received at central monitoring station?
  • Fire Alarm Inspection Notes and Deficiencies

Related Fire Safety Checklists

Related Fire Prevention Checklists

Why Use This Fire Alarm System Annual Inspection and Test Checklist?

This fire alarm system annual inspection and test checklist helps security services teams maintain compliance and operational excellence. Designed for licensed fire alarm inspector / nicet-certified technician professionals, this checklist covers 14 critical inspection points across 3 sections. Recommended frequency: annually.

Ensures compliance with NFPA 72-2022 National Fire Alarm and Signaling Code Chapter 14, IFC International Fire Code Section 907, NFPA 70 NEC Article 760 Fire Alarm Circuits, UL 864 Control Units for Fire Alarm Systems, NICET Fire Alarm Systems Inspection and Testing Standards. Regulatory-aligned for audit readiness and inspection documentation.

Frequently Asked Questions

What does the Fire Alarm System Annual Inspection and Test Checklist cover?

This checklist covers 14 inspection items across 3 sections: Fire Alarm Control Panel Status, Detector and Initiating Device Testing, Notification Appliances and Power. It is designed for security services operations and compliance.

How often should this checklist be completed?

This checklist should be completed annually. Each completion takes approximately 2-8 hours depending on system size.

Who should use this Fire Alarm System Annual Inspection and Test Checklist?

This checklist is designed for Licensed Fire Alarm Inspector / NICET-Certified Technician professionals in the security services industry. It can be used for self-assessments, team audits, and regulatory compliance documentation.

Can I download this checklist as a PDF?

Yes, this checklist is available as a free PDF download. You can also use it digitally in the POPProbe mobile app for real-time data capture, photo documentation, and automatic reporting.

Browse More Checklists