Australia Building Fire Safety Inspection (AS 1851)
This building fire safety checklist ensures compliance with AS 1851 (Routine service of fire protection systems and equipment), Building Code of Australia (BCA/NCC), state/territory fire safety regulations, and relevant Australian Standards. Building owners and managers have obligations to maintain fire safety measures and ensure annual fire safety statements are prepared.
- Industry: Construction
- Frequency: Monthly / Quarterly / Annually per AS 1851
- Estimated Time: 30-45 minutes
- Role: Fire Safety Officer / Building Manager
- Total Items: 28
- Compliance: AS 1851, BCA/NCC, AS 2444, AS 1670, AS 2118
Fire Detection & Alarm Systems
Fire detection system inspection per AS 1851 and AS 1670.
- Fire alarm panel showing normal condition?
- Smoke/heat detectors unobstructed and clean?
- Manual call points accessible and visible?
- Alarm system tested within required interval?
- Fire indicator panel accessible to fire brigade?
Fire Extinguishers & Hose Reels
Portable fire equipment per AS 2444 and AS 1851.
- Fire extinguishers within service date (6-monthly)?
- Extinguishers in designated locations and visible?
- Correct extinguisher types for hazards present?
- Fire hose reels operational (water flow confirmed)?
- Fire equipment location signs in place (AS 2444)?
Sprinkler & Suppression Systems
Automatic fire suppression per AS 2118 and AS 1851.
- Sprinkler control valves in correct position (open)?
- 500mm clearance below sprinkler heads?
- Sprinkler heads free from paint, damage, corrosion?
- Fire pump operational and tested?
Emergency Egress & Exit Systems
Emergency exit and egress requirements per BCA/NCC.
- All exits clear and unobstructed?
- Exit signs illuminated and visible per AS 2293?
- Emergency lighting operational (90 min backup)?
- Fire doors self-closing, not wedged open?
- Stairwell pressurisation system operational (if fitted)?
Passive Fire Protection
Passive fire safety features assessment.
- Fire compartment walls intact (no breaches)?
- Fire-rated penetration seals intact?
- Fire collars on services penetrations intact?
- Ceiling tiles in place (no gaps in fire-rated ceilings)?
Fire Safety Management
Fire safety management and documentation.
- Annual fire safety statement current?
- Evacuation plan and diagrams current and displayed?
- Fire wardens appointed and trained (AS 3745)?
- Evacuation drill conducted within last 12 months?
- Additional observations
Related Fire Safety Checklists
- Australia Emergency Evacuation Plan Checklist (AS 3745)
- High-Rise Building Fire Safety and Life Safety Systems Inspection Checklist
- Fire Watch Duties Checklist - FREE PDF
- Fire Protection System Impairment Checklist - FREE PDF
- Fire Safety NOC Inspection Checklist - India
- Workplace Fire Safety Inspection Checklist - India
- Inspeccion de Extintores y Seguridad Contra Incendios
- Fire Extinguisher Annual Maintenance - FREE PDF
Related Fire Prevention Checklists
- Fire Watch Duties Checklist - FREE PDF - FREE Download
- Fire Protection System Impairment Checklist - FREE PDF - FREE Download
- Fire Prevention Audit - FREE PDF - FREE Download
- Electrical Fire Prevention Inspection - FREE PDF - FREE Download
- Flammable Liquid Storage Inspection - FREE PDF - FREE Download
- Designated Smoking Area Inspection - FREE PDF - FREE Download
- Commercial Kitchen Hood Inspection - FREE PDF - FREE Download
- Kitchen Fire Suppression System Inspection - FREE PDF - FREE Download
- Fire Risk Assessment - FREE PDF - FREE Download
- Fire Warden/Marshal Duties Checklist - FREE PDF - FREE Download
Why Use This Australia Building Fire Safety Inspection (AS 1851)?
This australia building fire safety inspection (as 1851) helps construction teams maintain compliance and operational excellence. Designed for fire safety officer / building manager professionals, this checklist covers 28 critical inspection points across 6 sections. Recommended frequency: monthly / quarterly / annually per as 1851.
Ensures compliance with AS 1851, BCA/NCC, AS 2444, AS 1670, AS 2118, State Fire Safety Regulations. Regulatory-aligned for audit readiness and inspection documentation.
Frequently Asked Questions
What does the Australia Building Fire Safety Inspection (AS 1851) cover?
This checklist covers 28 inspection items across 6 sections: Fire Detection & Alarm Systems, Fire Extinguishers & Hose Reels, Sprinkler & Suppression Systems, Emergency Egress & Exit Systems, Passive Fire Protection, Fire Safety Management. It is designed for construction operations and compliance.
How often should this checklist be completed?
This checklist should be completed monthly / quarterly / annually per as 1851. Each completion takes approximately 30-45 minutes.
Who should use this Australia Building Fire Safety Inspection (AS 1851)?
This checklist is designed for Fire Safety Officer / Building Manager professionals in the construction industry. It can be used for self-assessments, team audits, and regulatory compliance documentation.
Can I download this checklist as a PDF?
Yes, this checklist is available as a free PDF download. You can also use it digitally in the POPProbe mobile app for real-time data capture, photo documentation, and automatic reporting.